204-0001 Fike TWINFLEX Multipoint ASD Detector Sounder
Using the ASD Multipoint detector with sounder and/or strobe as part of the TWINFLEXpro 2-wire fire alarm system means that when a detector is wired in, so is an optional sounder, with no extra wiring required. This greatly reduces the number of points that need to be installed – and the time it takes to install! In fact, with the TWINFLEXpro exclusive 2-wire design, installation savings can be as high as 40%. Multipoint offers 7 different modes of detection, which means one device can suit multiple applications. Whatever type of detection is required, it can be selected with an easy flick of a switch at the time of commissioning.
- Sounders can be run on the same pair of wires as detectors and/or call points
- No extra devices needed for audible warning
- Can differentiate between call point, smoke and heat alarms
- Two sound volumes easily selectable by dil switch
Using patented, advanced optical scatter sensor design and sophisticated electronic technology, Fike delivers reliable smoke and/or heat detection significantly reducing the risk of nuisance fire alarms.
Key Features:
- 7 modes of fire detection including combined smoke/heat
- Optional built-in sounder and/or strobe in a single device
- Self-calibrates every 6 hours
- Continuously monitors for dust contamination
- Easily removable for maintenance at height
Modes of Detection:
- Smoke 1: Used where ionisation detectors are normally fitted, especially when there are high ceilings or a risk of free burning fires (chemical stores etc.) or fires that need to be detected extremely quickly.
- Smoke 2: Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes.
- Smoke 3: Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature, means that a higher concentration of smoke needs to be present for a constant time period, before a fire decision is made. For example, this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.
- Heat 1 (Rate of Rise): Used where a standard rate of rise detector would normally be used.
- Heat 2 (Standard Fixed Temperature – 58ºC approx.): Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc.
- Heat 3 (High Fixed Temperature – 90ºC approx.): Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens, boiler rooms etc.